{"id":22,"date":"2012-08-22T16:20:49","date_gmt":"2012-08-22T14:20:49","guid":{"rendered":"http:\/\/dynamolab.umed.pl\/?page_id=22"},"modified":"2021-06-08T14:29:07","modified_gmt":"2021-06-08T12:29:07","slug":"analiza-czynnosci-ruchowych","status":"publish","type":"page","link":"https:\/\/dynamolab.umed.pl\/?page_id=22","title":{"rendered":"<!--:pl-->Analiza czynno\u015bci ruchowych<!--:--><!--:en-->Analysis of motor function <!--:-->"},"content":{"rendered":"<p><!--:pl--><\/p>\n<p style=\"text-align: justify;\"><strong>BTS Smart DX 7000<\/strong> to wydajny system do kompleksowej analizy ruchu cia\u0142a. System sk\u0142ada si\u0119 z 8 kamer TVC emituj\u0105cych promieniowanie IR o cz\u0119stotliwo\u015bci 500Hz przy maksymalnej rozdzielczo\u015bci. Kamery posiadaj\u0105 system rozpoznawania marker\u00f3w w technologii \u201eblob\u201d w skali szaro\u015bci (obszary o podobnej intensywno\u015bci) oraz umo\u017cliwiaj\u0105 pomiar ruchu w utrudnionych warunkach o\u015bwietlenia (np. pe\u0142ne \u015bwiat\u0142o s\u0142oneczne, brak pe\u0142nego o\u015bwietlenia sztucznego).<\/p>\n<p style=\"text-align: justify;\">Zarejestrowane przez kamery dane, s\u0105 zbierane i analizowane za pomoc\u0105 specjalistycznego oprogramowania, pozwalaj\u0105cego na:<br \/>\n&#8211; automatyczne \u015bledzenie danych w trakcie badania,<br \/>\n&#8211; kompletn\u0105 synchronizacj\u0119 danych kinematycznych, kinetycznych, sygna\u0142u EMG i obrazu video,<br \/>\n-mo\u017cliwo\u015b\u0107 eksportowania zebranych danych w dost\u0119pnych formatach, do dalszej analizy<br \/>\nstatystycznej,<br \/>\n&#8211; automatyczne obliczanie zadanych parametr\u00f3w na podstawie przyj\u0119tego protoko\u0142u,<br \/>\n&#8211; rejestracj\u0119 danych kinematycznych i sygna\u0142u analogowego,<br \/>\n&#8211; graficzn\u0105 prezentacj\u0119 danych w czasie rzeczywistym,<br \/>\n&#8211; rekonstrukcj\u0119 3D i automatyczne oznaczanie marker\u00f3w,<br \/>\n&#8211; wizualizacj\u0119 i edycj\u0119 pozycji marker\u00f3w<\/p>\n<p style=\"text-align: justify;\">Analiza jest nieinwazyjna, gdy\u017c markery naklejane s\u0105 na sk\u00f3r\u0119 pacjenta. System mo\u017ce by\u0107 stosowany na wolnym powietrzu.<\/p>\n<p style=\"text-align: justify;\">Dane s\u0142u\u017c\u0105 do:<br \/>\n&#8211;&nbsp; oceny uk\u0142adu ruchu pacjenta,<br \/>\n&#8211;&nbsp; ustalenia stopnia dysfunkcji,<br \/>\n&#8211;&nbsp; zaplanowania strategii leczenia,<br \/>\n&#8211;&nbsp; zaplanowania treningu,<br \/>\n&#8211;&nbsp; oceny skuteczno\u015bci prowadzonego treningu lub procesu terapeutycznego.<\/p>\n<p style=\"text-align: justify;\"><a href=\"http:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/IMG_02041.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-270 size-medium\" title=\"IMG_0204\" src=\"http:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/IMG_02041-300x200.jpg\" alt=\"analiza czynno\u015bci ruchowych\" width=\"300\" height=\"200\" srcset=\"https:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/IMG_02041-300x200.jpg 300w, https:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/IMG_02041-1024x682.jpg 1024w, https:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/IMG_02041-600x400.jpg 600w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a> <a href=\"http:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_38651.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-271 size-medium\" title=\"DSC_3865\" src=\"http:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_38651-300x200.jpg\" alt=\"BTS\" width=\"300\" height=\"200\" srcset=\"https:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_38651-300x200.jpg 300w, https:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_38651-1024x685.jpg 1024w, https:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_38651-600x401.jpg 600w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><br \/>\n<a href=\"http:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_37841.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-272 size-medium\" title=\"DSC_3784\" src=\"http:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_37841-200x300.jpg\" alt=\"BTS Smart\" width=\"200\" height=\"300\" srcset=\"https:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_37841-200x300.jpg 200w, https:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_37841-685x1024.jpg 685w, https:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_37841-600x896.jpg 600w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><\/a><br \/>\nBie\u017cnia diagnostyczno \u2013 pomiarowa&nbsp;<strong>H\/P Cosmos Mercury Med 4.0 Gaitway IIS <\/strong>(do analizy chodu z kamerami video)wyposa\u017cona jest w modu\u0142y do analizy lokomocji i ruchu z mo\u017cliwo\u015bci\u0105 oceny si\u0142 reakcji pod\u0142o\u017ca z wykorzystaniem platform dynamograficznych oraz analiz\u0105 kinetyczn\u0105.<\/p>\n<p style=\"text-align: justify;\">W urz\u0105dzeniu zosta\u0142y wykorzystane p\u0142yty nacisku <strong>Kistler\u2019a<\/strong>, kt\u00f3re s\u0105 szeroko stosowane w pracach badawczych analizy poruszania si\u0119 w otoczeniu klinicznym i sportowym.<\/p>\n<p style=\"text-align: justify;\">Zalety stosowania bie\u017cni ruchomej znajduj\u0105 zastosowanie, podczas pracy ze sportowcami oraz pacjentami. Urz\u0105dzenie zapewnia bowiem stabilny ch\u00f3d. Do obs\u0142ugi urz\u0105dzenia wykorzystano oprogramowanie <strong>Gaitway, <\/strong>kt\u00f3re zbiera dane z czujnik\u00f3w nacisku, ulokowanych w bie\u017cni ruchomej, oddziela lew\u0105 i praw\u0105 stop\u0119, rysuje wyniki, a tak\u017ce umo\u017cliwia u\u017cytkownikowi wydruk i eksport danych. Pomiary nacisku pionowego pozwalaj\u0105 obliczy\u0107 nacisk, przemieszczenie \u015brodka nacisku (COP) i chwilowe (zale\u017cne od czasu) parametry ruchu.<\/p>\n<p><!--:--><!--:en--><\/p>\n<p style=\"text-align: justify;\"><strong>BTS Smart DX 7000 <\/strong>is a system for comprehensive analysis of body movement. The system consists of 8 TVC cameras, emitting IR radiation with a frequency of 500Hz at maximum resolution. The cameras detect markers in &#8222;blob&#8221; technology in the gray scale (areas of similar intensity) and allow the measurement of movement under difficult lighting conditions (for example: full sunlight, lack of full artificial lighting).<\/p>\n<p>Data recorded by the camera are collected and analyzed using specialized software, allowing:<br \/>\n&#8211; automatic tracking of data during the study,<br \/>\n&#8211; the complete synchronization of kinematic data, kinetic data, EMG signal and the video image,<br \/>\n&#8211; the ability to export collected data in accessible formats for statistical analysis,<br \/>\n&#8211; automatic calculation of the input parameters based on the particular protocol,<br \/>\n&#8211; registration of kinematic data and analog signal,<br \/>\n&#8211; graphical presentation of data in real time,<br \/>\n&#8211; 3D reconstruction and automatic tracking of markers,<br \/>\n&#8211; visualization and editing of markers position.<\/p>\n<p style=\"text-align: justify;\">The analysis is non-invasive, since markers are placed on the patient skin with a proper tape. The system can be used outdoors.<\/p>\n<p>The data are used to:<br \/>\n&#8211; evaluate of the patient movement,<br \/>\n&#8211; determine the degree of dysfunction,<br \/>\n&#8211; plan the treatment,<br \/>\n&#8211; plan the training,<br \/>\n&#8211; evaluate the effectiveness of training or the therapeutic process.<\/p>\n<p><a href=\"http:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/IMG_02041.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-270\" title=\"IMG_0204\" src=\"http:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/IMG_02041-300x200.jpg\" alt=\"\" width=\"300\" height=\"200\" srcset=\"https:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/IMG_02041-300x200.jpg 300w, https:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/IMG_02041-1024x682.jpg 1024w, https:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/IMG_02041-600x400.jpg 600w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a> <a href=\"http:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_38651.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-271 size-medium\" title=\"DSC_3865\" src=\"http:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_38651-300x200.jpg\" alt=\"BTS\" width=\"300\" height=\"200\" srcset=\"https:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_38651-300x200.jpg 300w, https:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_38651-1024x685.jpg 1024w, https:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_38651-600x401.jpg 600w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p><a href=\"http:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_37841.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-272 size-medium\" title=\"DSC_3784\" src=\"http:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_37841-200x300.jpg\" alt=\"BTS Smart\" width=\"200\" height=\"300\" srcset=\"https:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_37841-200x300.jpg 200w, https:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_37841-685x1024.jpg 685w, https:\/\/dynamolab.umed.pl\/wp-content\/uploads\/2012\/08\/DSC_37841-600x896.jpg 600w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify;\"><strong>H\/P Cosmos Mercury Med 4.0 Gaitway IIS <\/strong>(with video cameras for gait analysis) allows kinetic analysis of movement as well as assessment of ground reaction forces with dynamographic platforms.<\/p>\n<p style=\"text-align: justify;\">The device contains <strong>Kistler<\/strong> pressure plates, which are applied in research analysis of movement, in the clinical setting and sports.<\/p>\n<p style=\"text-align: justify;\">The treadmill is useful for athletes and patients providing a stable gait. Moreover, <strong>Gaitway<\/strong> software collects data from pressure sensors located on a treadmill, separates the left and right footprint, draws results and allows the user to print and export data. The measurements allow to calculate the vertical pressure, displacement of the Center of Pressure (COP) and instantaneous (time dependent) movement parameters.<\/p>\n<p><!--:--><\/p>\n","protected":false},"excerpt":{"rendered":"<p>BTS Smart DX 7000 to wydajny system do kompleksowej analizy ruchu cia\u0142a. System sk\u0142ada si\u0119 z 8 kamer TVC emituj\u0105cych promieniowanie IR o cz\u0119stotliwo\u015bci 500Hz przy maksymalnej rozdzielczo\u015bci. Kamery posiadaj\u0105 system rozpoznawania marker\u00f3w w technologii \u201eblob\u201d w skali szaro\u015bci (obszary o podobnej intensywno\u015bci) oraz umo\u017cliwiaj\u0105 pomiar ruchu w utrudnionych warunkach o\u015bwietlenia (np. pe\u0142ne \u015bwiat\u0142o s\u0142oneczne,<\/p>\n","protected":false},"author":7,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ngg_post_thumbnail":0,"footnotes":""},"class_list":["post-22","page","type-page","status-publish","hentry"],"publishpress_future_action":{"enabled":false,"date":"2026-08-26 14:02:22","action":"change-status","newStatus":"draft","terms":[],"taxonomy":"","extraData":[]},"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/dynamolab.umed.pl\/index.php?rest_route=\/wp\/v2\/pages\/22","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dynamolab.umed.pl\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/dynamolab.umed.pl\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/dynamolab.umed.pl\/index.php?rest_route=\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/dynamolab.umed.pl\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=22"}],"version-history":[{"count":20,"href":"https:\/\/dynamolab.umed.pl\/index.php?rest_route=\/wp\/v2\/pages\/22\/revisions"}],"predecessor-version":[{"id":931,"href":"https:\/\/dynamolab.umed.pl\/index.php?rest_route=\/wp\/v2\/pages\/22\/revisions\/931"}],"wp:attachment":[{"href":"https:\/\/dynamolab.umed.pl\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=22"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}